products category
Related articles
產品中心/ products
介(jie)(jie)質損(sun)耗測(ce)(ce)量(liang)儀廠(chang)商是發電(dian)(dian)(dian)廠(chang)、變(bian)電(dian)(dian)(dian)站等現場或實驗室測(ce)(ce)試(shi)各種高壓(ya)電(dian)(dian)(dian)力設備介(jie)(jie)損(sun)正切值及電(dian)(dian)(dian)容(rong)量(liang)的高精度測(ce)(ce)試(shi)儀器。儀器為一體化結構,內置介(jie)(jie)損(sun)測(ce)(ce)試(shi)電(dian)(dian)(dian)橋,可(ke)變(bian)頻(pin)調壓(ya)電(dian)(dian)(dian)源,升壓(ya)變(bian)壓(ya)器和(he)SF6 高穩定度標準電(dian)(dian)(dian)容(rong)器。
聯系電話:17351382898
介質損耗測量儀廠商是發電廠、變電站(zhan)等(deng)現場或實驗室測(ce)試各(ge)種高壓電力設(she)備介損正切(qie)值(zhi)及(ji)電容量的高精度測(ce)試儀器。儀器為(wei)一體(ti)(ti)化結構,內置(zhi)介損測(ce)試電橋,可變頻調壓電源,升壓變壓器和SF6 高穩定度標準(zhun)電容(rong)器(qi)。測試高壓(ya)源由儀(yi)器(qi)內部的逆變器(qi)產生,經變壓(ya)器(qi)升(sheng)壓(ya)后(hou)用于被(bei)試品測試。頻率可(ke)變為45Hz或55Hz,55Hz或65Hz,采用(yong)數字陷波技術,避開(kai)了工頻電場(chang)對測試的(de)干擾,從(cong)根本上解(jie)決了強電場(chang)干擾下準確測量(liang)的(de)難題。同時適用(yong)于全部停電后用(yong)發電機供電檢測的(de)場(chang)合。
介質損耗測量儀廠商特點:
超大液晶中文顯示
儀器配備了大(da)屏幕(mu)(105mm×65mm)中文(wen)菜單界面(mian),屏(ping)顯分為(wei)(wei)左右(you)兩部分,左邊為(wei)(wei)功能菜單區,右(you)邊為(wei)(wei)相關狀(zhuang)態信(xin)息提示,每一步都非常(chang)清楚(chu),操(cao)作人員(yuan)不需要(yao)專業(ye)培訓就能使用。一次操(cao)作,微(wei)機自動完(wan)成(cheng)全過程的測(ce)量,是目前(qian)非常(chang)理想的介損測(ce)量設備。
海量存儲數據
儀器內部配備有日歷芯(xin)片(pian)和大容量(liang)存儲器,能將檢測(ce)結果按時間(jian)順(shun)序(xu)保(bao)存,隨時可以(yi)查看(kan)歷史(shi)記(ji)錄,并可以(yi)打(da)印輸出;
科(ke)學(xue)*數(shu)據管理
儀器(qi)數據可(ke)以(yi)通過(guo)U盤導出,可在任意一臺(tai)PC機上通(tong)過我(wo)公司軟(ruan)件,查看和管理(li)數據并(bing)可生(sheng)成工(gong)作報告。
多種測試模式
儀器(qi)能夠分(fen)別使用內(nei)高(gao)壓、外(wai)高(gao)壓、內(nei)標(biao)準(zhun)、外(wai)標(biao)準(zhun)、正接(jie)法(fa)、反接(jie)法(fa)、自激(ji)法(fa)等多種(zhong)方式測(ce)試(shi);在外(wai)標(biao)準(zhun)外(wai)高(gao)壓情況下可(ke)以做(zuo)高(gao)電壓(大于10kV)介質損耗。
多(duo)重保護安全(quan)可靠(kao)
儀(yi)(yi)器(qi)具(ju)(ju)備輸(shu)入電壓(ya)波(bo)動、輸(shu)出短路、過壓(ya)、過流、溫度等(deng)多重保(bao)護措施(shi),保(bao)證了儀(yi)(yi)器(qi)安(an)全、可靠(kao)。儀(yi)(yi)器(qi)還(huan)具(ju)(ju)備接地(di)檢測功能,確保(bao)不接地(di)設備不允許升壓(ya)。
工作原(yuan)理
在(zai)交(jiao)流(liu)電(dian)(dian)壓(ya)(ya)作(zuo)用(yong)下,電(dian)(dian)介質(zhi)(zhi)(zhi)要(yao)消耗(hao)部(bu)分(fen)電(dian)(dian)能(neng),這部(bu)分(fen)電(dian)(dian)能(neng)將轉(zhuan)變為(wei)(wei)熱能(neng)產生損(sun)耗(hao)。這種(zhong)能(neng)量損(sun)耗(hao)叫(jiao)做電(dian)(dian)介質(zhi)(zhi)(zhi)的(de)(de)損(sun)耗(hao)。當(dang)電(dian)(dian)介質(zhi)(zhi)(zhi)上施(shi)加(jia)交(jiao)流(liu)電(dian)(dian)壓(ya)(ya)時,電(dian)(dian)介質(zhi)(zhi)(zhi)中的(de)(de)電(dian)(dian)壓(ya)(ya)和電(dian)(dian)流(liu)間成(cheng)在(zai)相角(jiao)(jiao)差ψ,ψ的(de)(de)余角(jiao)(jiao)δ稱為(wei)(wei)介質(zhi)(zhi)(zhi)損(sun)耗(hao)角(jiao)(jiao),δ的(de)(de)正切tgδ稱為介質損耗角正(zheng)切。tgδ值是用來衡(heng)量電(dian)介質(zhi)損耗的參(can)數(shu)。儀器測量線路包括一標準回路(Cn)和一被試回路(Cx),如圖2—1所示(shi)。標準回(hui)路(lu)由(you)內(nei)置(zhi)高穩(wen)定度(du)標準電容器與測(ce)量(liang)線(xian)路(lu)組(zu)成,被(bei)(bei)試(shi)回(hui)路(lu)由(you)被(bei)(bei)試(shi)品(pin)和測(ce)量(liang)線(xian)路(lu)組(zu)成。測(ce)量(liang)線(xian)路(lu)由(you)取樣電阻與前置(zhi)放大器和A/D轉換器組(zu)成。通(tong)(tong)過測(ce)(ce)量電路(lu)分別測(ce)(ce)得標準(zhun)回路(lu)電流與被試回路(lu)電流幅值及其相位差,再由(you)數(shu)字信號處理器運(yun)用數(shu)字化實(shi)時采(cai)集方法,通(tong)(tong)過矢量運(yun)算得出試品的(de)電容值和介質損耗(hao)正切(qie)值。儀(yi)器內(nei)部已經采(cai)用了抗干擾措施(shi),保證(zheng)在外電場(chang)干擾下準(zhun)確測(ce)(ce)量。
主(zhu)要技術參(can)數
1 | 使用條件(jian) | -15℃∽40℃ | RH<80% | ||
2 | 抗干擾原(yuan)理 | 變頻法(fa) | |||
3 | 電 源(yuan) | AC 220V±10% | 允(yun)許發電機 | ||
4 | 高壓(ya)輸(shu)出 | 0.5KV∽10KV | 每隔0.1kV | ||
精 度 | 2% | ||||
大電流(liu) | 200mA | ||||
容 量 | 1500VA | ||||
5 | 自激電源 | AC 0V∽50V/15A | 45HZ/55HZ 55HZ/65HZ | ||
6 | 分 辨(bian) 率(lv) | tgδ: 0.001% | Cx: 0.01pF | ||
7 | 精 度 | △tgδ:±(讀數*1.0%+0.040%) | |||
△C x :±(讀數*1.0%+1.00PF) | |||||
8 | 測量范圍 | tgδ | 無限制 | ||
C x | 15pF < Cx < 300nF | ||||
| 10KV | Cx < 60 nF | |||
| 5KV | Cx < 150 nF | |||
| 1KV | Cx < 300 nF | |||
CVT測試 | Cx < 300 nF | ||||
9 | CVT變(bian)比范圍 | 10∽10000 | |||
CVT變(bian)比精度 | 0.1% | ||||
CVT變比分辨率 | 0.01 | ||||
10 | 外(wai)型(xing)尺寸 | 430(L)×330(W)×330(H) | |||
11 | 存儲(chu)器大小 | 200 組(zu) 支持U盤數據(ju)存儲 | |||
12 | 重 量 | 28 Kg | |||